{"id":2641,"date":"2026-04-01T01:53:20","date_gmt":"2026-04-01T01:53:20","guid":{"rendered":"https:\/\/www.fuyao-quartz.com\/?p=2641"},"modified":"2026-04-02T06:53:43","modified_gmt":"2026-04-02T06:53:43","slug":"what-is-the-difference-between-g-652-d-g-657-a1-and-g-657-a2-singlemode-fiber","status":"publish","type":"post","link":"https:\/\/www.fuyao-quartz.com\/tr\/what-is-the-difference-between-g-652-d-g-657-a1-and-g-657-a2-singlemode-fiber\/","title":{"rendered":"G.652.D, G.657.A1 ve G.657.A2 Tekli Mod Fiber Aras\u0131ndaki Fark Nedir?"},"content":{"rendered":"<p>Tek modlu optik fiber, modern telekom\u00fcnikasyon ve veri iletim sistemlerinin bel kemi\u011fidir. Bir\u00e7ok m\u00fchendis tek modlu fiberi standart 9\/125 \u03bcm \u00e7ekirdek\/kaplama yap\u0131s\u0131 ile ili\u015fkilendirirken, performans \u00f6zellikleri fiber standard\u0131na ba\u011fl\u0131 olarak \u00f6nemli \u00f6l\u00e7\u00fcde de\u011fi\u015fir. En yayg\u0131n kullan\u0131lanlar aras\u0131nda, her biri Uluslararas\u0131 Telekom\u00fcnikasyon Birli\u011fi (ITU-T) taraf\u0131ndan tan\u0131mlanan G.652.D, G.657.A1 ve G.657.A2 bulunmaktad\u0131r.<\/p>\n\n\n\n<p>Bu makale, bu elyaf t\u00fcrlerinin teknik ancak eri\u015filebilir bir kar\u015f\u0131la\u015ft\u0131rmas\u0131n\u0131 sunmakta ve \u00f6zellikle nedenlerine odaklanmaktad\u0131r <a href=\"https:\/\/www.fuyao-quartz.com\/tr\/product\/g-657-a2-bend-insensitive-single-mode-optical-fiber-for-ftth-indoor-cabling-data-centers\/\">G.657.A2 b\u00fck\u00fclmeye duyars\u0131z fiber<\/a> y\u00fcksek yo\u011funluklu ve k\u0131s\u0131tl\u0131 kurulumlar i\u00e7in tercih edilen \u00e7\u00f6z\u00fcm haline gelmektedir.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"682\" height=\"600\" src=\"https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/Bending-Radii-for-Singlemode-Fibres.webp\" alt=\"\" class=\"wp-image-2642\" srcset=\"https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/Bending-Radii-for-Singlemode-Fibres.webp 682w, https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/Bending-Radii-for-Singlemode-Fibres-300x264.webp 300w, https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/Bending-Radii-for-Singlemode-Fibres-14x12.webp 14w, https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/Bending-Radii-for-Singlemode-Fibres-600x528.webp 600w\" sizes=\"(max-width: 682px) 100vw, 682px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">1. Tekli Mod Fiber Standartlar\u0131n\u0131n Temelleri<\/h2>\n\n\n\n<p>ITU-T \u00f6nerileri, fiber optik performans\u0131n\u0131 \u015fu \u015fekilde tan\u0131mlamaktad\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Geometrik \u00f6zellikler<\/strong> (\u00e7ekirdek\/kaplama \u00e7ap\u0131)<\/li>\n\n\n\n<li><strong>\u0130letim \u00f6zellikleri<\/strong> (zay\u0131flama, da\u011f\u0131lma)<\/li>\n\n\n\n<li><strong>Mekanik g\u00fcvenilirlik<\/strong><\/li>\n\n\n\n<li><strong>B\u00fckme performans\u0131<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Her \u00fc\u00e7 fiber tipi de (G.652.D, G.657.A1 ve G.657.A2) ayn\u0131 fiziksel boyutlara sahiptir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00c7ekirdek \u00e7ap\u0131: ~9 \u03bcm<\/li>\n\n\n\n<li>Kaplama \u00e7ap\u0131: 125 \u03bcm<\/li>\n<\/ul>\n\n\n\n<p>Bu, ekleme ve konnekt\u00f6rlemede tam uyumluluk sa\u011flayarak \u00e7o\u011fu a\u011fda birbirlerinin yerine kullan\u0131labilmelerine olanak tan\u0131r.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"800\" height=\"533\" src=\"https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/G.657-2012-01-800x533-1.webp\" alt=\"\" class=\"wp-image-2643\" srcset=\"https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/G.657-2012-01-800x533-1.webp 800w, https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/G.657-2012-01-800x533-1-300x200.webp 300w, https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/G.657-2012-01-800x533-1-768x512.webp 768w, https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/G.657-2012-01-800x533-1-18x12.webp 18w, https:\/\/www.fuyao-quartz.com\/wp-content\/uploads\/2026\/04\/G.657-2012-01-800x533-1-600x400.webp 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">2. G.652.D: Geleneksel Standart<\/h2>\n\n\n\n<p>G.652.D en yayg\u0131n olarak kullan\u0131lan tek modlu fiber standard\u0131d\u0131r ve uzun mesafeli ve metro a\u011flar\u0131 i\u00e7in temel te\u015fkil eder.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Temel \u00d6zellikler:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1310 nm ve 1550 nm iletim pencereleri i\u00e7in optimize edilmi\u015ftir<\/li>\n\n\n\n<li>D\u00fc\u015f\u00fck zay\u0131flama ve da\u011f\u0131lma<\/li>\n\n\n\n<li>CWDM\/DWDM gibi geli\u015fmi\u015f teknolojileri destekler<\/li>\n\n\n\n<li>Minimum b\u00fck\u00fclme yar\u0131\u00e7ap\u0131: ~30 mm<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">S\u0131n\u0131rlamalar:<\/h3>\n\n\n\n<p>G.652.D iletimde m\u00fckemmel performans g\u00f6sterirken, b\u00fck\u00fclme kay\u0131plar\u0131na kar\u015f\u0131 hassast\u0131r, bu da onu daha az uygun hale getirir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>S\u0131k\u0131 kablo y\u00f6nlendirmesi<\/li>\n\n\n\n<li>Veri merkezi patch panelleri<\/li>\n\n\n\n<li>Y\u00fcksek yo\u011funluklu raflar<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">3. G.657 Standard\u0131: B\u00fck\u00fclmeye Duyars\u0131z Fiber<\/h2>\n\n\n\n<p>Modern a\u011flardaki kurulum zorluklar\u0131n\u0131 ele almak i\u00e7in ITU, \u00f6zellikle b\u00fck\u00fclmeye kar\u015f\u0131 duyars\u0131z performans\u0131 hedefleyen G.657'yi tan\u0131tt\u0131.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">S\u0131n\u0131fland\u0131rma:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Kategori A (G.657.A1, G.657.A2): G.652.D ile geriye d\u00f6n\u00fck uyumlu<\/li>\n\n\n\n<li><strong>Kategori B (G.657.B2, B3)<\/strong>: Ultra s\u0131k\u0131 b\u00fckme, ancak daha az uyumluluk<\/li>\n<\/ul>\n\n\n\n<p>Pratik da\u011f\u0131t\u0131mlarda, <strong>Kategori A lifleri bask\u0131nd\u0131r<\/strong>, \u00f6zellikle A1 ve A2.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. G.657.A1 vs G.652.D<\/h2>\n\n\n\n<p>G.657.A1, \u00f6ncelikle b\u00fckme performans\u0131nda G.652.D'yi geli\u015ftirir.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parametre<\/th><th>G.652.D<\/th><th>G.657.A1<\/th><\/tr><\/thead><tbody><tr><td>B\u00fck\u00fclme Yar\u0131\u00e7ap\u0131<\/td><td>~30 mm<\/td><td>~10 mm<\/td><\/tr><tr><td>Uyumluluk<\/td><td>\u2014<\/td><td>G.652.D ile tam uyumlu<\/td><\/tr><tr><td>Uygulama<\/td><td>Uzun mesafeli a\u011flar<\/td><td>Eri\u015fim a\u011flar\u0131, orta yo\u011funlukta<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u0130\u00e7g\u00f6r\u00fc:<\/h3>\n\n\n\n<p>G.657.A1 b\u00fck\u00fclme tolerans\u0131nda 3 kat iyile\u015fme sa\u011flayarak orta derecede k\u0131s\u0131tl\u0131 ortamlarda sinyal kayb\u0131n\u0131 \u00f6nemli \u00f6l\u00e7\u00fcde azalt\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. G.657.A2: Geli\u015fmi\u015f B\u00fck\u00fclme Duyars\u0131zl\u0131\u011f\u0131<\/h2>\n\n\n\n<p>G.657.A2, iletim performans\u0131ndan \u00f6d\u00fcn vermeden \u00fcst\u00fcn esneklik sunan daha ileri bir evrimi temsil eder.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parametre<\/th><th>G.657.A1<\/th><th>G.657.A2<\/th><\/tr><\/thead><tbody><tr><td>Minimum B\u00fck\u00fclme Yar\u0131\u00e7ap\u0131<\/td><td>10 mm<\/td><td><strong>7,5 mm<\/strong><\/td><\/tr><tr><td>Uyumluluk<\/td><td>G.652.D<\/td><td>G.652.D<\/td><\/tr><tr><td>Tipik Kullan\u0131m<\/td><td>Eri\u015fim a\u011flar\u0131<\/td><td>Y\u00fcksek yo\u011funluklu, dar alanlar<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Teknik Avantajlar:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Geli\u015ftirilmi\u015f <strong>makro b\u00fck\u00fclme kayb\u0131 direnci<\/strong><\/li>\n\n\n\n<li>D\u00fc\u015f\u00fck s\u0131cakl\u0131klarda bile istikrarl\u0131 performans <strong>s\u0131k\u0131 g\u00fczergah ko\u015fullar\u0131<\/strong><\/li>\n\n\n\n<li>\u015eunlar i\u00e7in ideal <strong>k\u0131sa yar\u0131\u00e7apl\u0131 kablo y\u00f6netimi senaryolar\u0131<\/strong><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">6. Modern A\u011flarda G.657.A2 Neden Tercih Edilir?<\/h2>\n\n\n\n<p>Veri merkezlerinin, FTTH (Eve Kadar Fiber) ve 5G altyap\u0131s\u0131n\u0131n h\u0131zla b\u00fcy\u00fcmesiyle kurulum ortamlar\u0131 giderek daha kompakt hale geliyor.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">G.657.A2'nin Temel Faydalar\u0131:<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">1. Ultra S\u0131k\u0131 B\u00fck\u00fclme Yar\u0131\u00e7ap\u0131<\/h4>\n\n\n\n<p>Minimum 7,5 mm'lik b\u00fck\u00fclme yar\u0131\u00e7ap\u0131, \u00f6nemli bir sinyal bozulmas\u0131 olmadan son derece dar alanlarda y\u00f6nlendirme yap\u0131lmas\u0131na olanak tan\u0131r.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">2. Yo\u011fun Ortamlarda Y\u00fcksek G\u00fcvenilirlik<\/h4>\n\n\n\n<p>\u0130\u00e7inde bile d\u00fc\u015f\u00fck ekleme kayb\u0131n\u0131 korur:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Yama panelleri<\/li>\n\n\n\n<li>Sunucu raflar\u0131<\/li>\n\n\n\n<li>Muhafazalar<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">3. Tam Geriye D\u00f6n\u00fck Uyumluluk<\/h4>\n\n\n\n<p>Mevcut G.652.D altyap\u0131s\u0131yla sorunsuz bir \u015fekilde entegre olarak uygun maliyetli y\u00fckseltmelere olanak sa\u011flar.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">4. Azalt\u0131lm\u0131\u015f Kurulum Riski<\/h4>\n\n\n\n<p>Montajc\u0131 kullan\u0131m\u0131na kar\u015f\u0131 daha az hassasiyet azal\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Mikro b\u00fck\u00fclme kay\u0131plar\u0131<\/li>\n\n\n\n<li>Uzun vadeli ar\u0131za oranlar\u0131<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">7. Tipik Uygulamalar<\/h2>\n\n\n\n<p>G.657.A2 b\u00fck\u00fclmeye kar\u015f\u0131 hassas olmayan fiber \u00f6zellikle \u015funlar i\u00e7in uygundur:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Y\u00fcksek yo\u011funluklu veri merkezleri<\/li>\n\n\n\n<li>FTTx a\u011flar\u0131 (\u00f6zellikle i\u00e7 mekan kablolamas\u0131)<\/li>\n\n\n\n<li>Telekom\u00fcnikasyon dolaplar\u0131 ve kapaklar\u0131<\/li>\n\n\n\n<li>\u00c7oklu virajl\u0131 karma\u015f\u0131k y\u00f6nlendirme ortamlar\u0131<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">8. \u00dcr\u00fcn Tavsiyesi: G.657.A2 B\u00fck\u00fclmeye Duyars\u0131z Tek Modlu Optik Fiber<\/h2>\n\n\n\n<p>Her ikisini de gerektiren modern optik a\u011flar i\u00e7in <strong>performans ve esneklik<\/strong>, bizim <strong>G.657.A2 B\u00fck\u00fclmeye Duyars\u0131z Tek Modlu Optik Fiber<\/strong> optimum bir \u00e7\u00f6z\u00fcm sunar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Temel \u00d6zellikler:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ITU-T G.657.A2 ve G.652.D ile uyumlu<\/li>\n\n\n\n<li>Minimum b\u00fck\u00fclme yar\u0131\u00e7ap\u0131: <strong>7,5 mm<\/strong><\/li>\n\n\n\n<li>D\u00fc\u015f\u00fck zay\u0131flama ve ekleme kayb\u0131<\/li>\n\n\n\n<li>\u015eunlar i\u00e7in optimize edilmi\u015ftir <strong>1310 \/ 1550 nm iletim<\/strong><\/li>\n\n\n\n<li>Standart konekt\u00f6rlerle uyumludur (LC, SC, FC, APC\/UPC)<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">M\u00fchendislik De\u011feri:<\/h3>\n\n\n\n<p>G.657.A2 fiberi benimseyerek a\u011f tasar\u0131mc\u0131lar\u0131 \u015funlar\u0131 yapabilir:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Performanstan \u00f6d\u00fcn vermeden kablo yo\u011funlu\u011funu art\u0131r\u0131n<\/li>\n\n\n\n<li>K\u0131s\u0131tl\u0131 mimarilerde kurulumu basitle\u015ftirin<\/li>\n\n\n\n<li>Uzun vadeli sistem istikrar\u0131n\u0131n iyile\u015ftirilmesi<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">9. Sonu\u00e7<\/h2>\n\n\n\n<p>G.652.D geleneksel da\u011f\u0131t\u0131mlar i\u00e7in end\u00fcstri standard\u0131 olmaya devam ederken, G.657.A1 ve G.657.A2 modern a\u011f ortamlar\u0131nda artan esneklik ihtiyac\u0131n\u0131 kar\u015f\u0131lamaktad\u0131r.<\/p>\n\n\n\n<p>Bunlar aras\u0131nda G.657.A2, en \u00e7ok y\u00f6nl\u00fc ve gelece\u011fe d\u00f6n\u00fck se\u00e7enek olarak \u00f6ne \u00e7\u0131kmaktad\u0131r:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>S\u0131k\u0131 b\u00fck\u00fclme tolerans\u0131<\/li>\n\n\n\n<li>Tam uyumluluk<\/li>\n\n\n\n<li>Y\u00fcksek iletim performans\u0131<\/li>\n<\/ul>\n\n\n\n<p>A\u011f altyap\u0131s\u0131 daha y\u00fcksek yo\u011funluk ve karma\u015f\u0131kl\u0131\u011fa do\u011fru geli\u015fmeye devam ettik\u00e7e, G.657.A2 b\u00fck\u00fclmeye duyars\u0131z fiber art\u0131k iste\u011fe ba\u011fl\u0131 de\u011fil, gerekli hale geliyor.<\/p>","protected":false},"excerpt":{"rendered":"<p>Singlemode optical fiber is the backbone of modern telecommunications and data transmission systems. While many engineers associate singlemode fiber with the standard 9\/125 \u03bcm core\/cladding structure, the performance characteristics vary significantly depending on the fiber standard. Among the most widely used are G.652.D, G.657.A1, and G.657.A2, each defined by the International Telecommunication Union (ITU-T). This [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2642,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[746,733,751,748,742,741,747,750,743,735,736,732,744,737,739,749,738,740,734,745],"class_list":["post-2641","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-9-125um-singlemode-fiber","tag-bend-insensitive-fiber","tag-bend-insensitive-singlemode-fiber","tag-cwdm-dwdm-fiber","tag-data-center-fiber-solutions","tag-fiber-optic-cable-types","tag-fiber-optic-compatibility","tag-fiber-patch-cable","tag-ftth-fiber-cable","tag-g-652-d-vs-g-657","tag-g-657-a1-vs-g-657-a2","tag-g-657-a2-fiber","tag-high-density-fiber-cabling","tag-itu-t-fiber-standards","tag-low-bending-loss-fiber","tag-low-insertion-loss-fiber","tag-optical-fiber-bend-radius","tag-os2-fiber","tag-singlemode-optical-fiber","tag-telecom-optical-fiber"],"_links":{"self":[{"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/posts\/2641","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/comments?post=2641"}],"version-history":[{"count":1,"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/posts\/2641\/revisions"}],"predecessor-version":[{"id":2644,"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/posts\/2641\/revisions\/2644"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/media\/2642"}],"wp:attachment":[{"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/media?parent=2641"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/categories?post=2641"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fuyao-quartz.com\/tr\/wp-json\/wp\/v2\/tags?post=2641"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}